Torus, Integrated flasher in lighthead), Prizm ii – Code 3 DuoBeam II User Manual

Page 6: And tricore, Modules with central controller, Flash pattern description

Advertising
background image

6

Torus

TM

(Integrated flasher in lighthead)

Flash Pattern Description

1. Cycle Flash (DEFAULT)--------------Cycles through various patterns @ 70 fpm

2. NFPA Quad Flash 80 FPM-----------Four Pulses per flash @ 80 fpm

3. Quad Flash 70 FPM--------------------Four Pulses per flash @ 70 fpm

4. Steadyburn-------------------------------Steady-Burn

5. Five Flash 70 FPM---------------------Five Pulses per flash @ 70 fpm

6. Triple Flash 70 FPM ------------------

Three Pulses per flash @ 70 fpm

7. Double Flash 70 FPM-----------------Two Pulses per flash @ 70 fpm

8. Single Flash 70 FPM------------------One Pulse per flash @ 70 fpm

9. Quad Pop Flash 70 FPM-------------Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm

10. Triple Pop Flash 70 FPM------------

Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm

11. Mod Flash

12. Cycle Flash 150 FPM-----------------Cycles through various patterns @ 150 fpm

13. Five Flash 150 FPM-------------------Five Pulses per flash @ 150 fpm

14. Quad Flash 150 FPM------------------Four Pulses per flash @ 150 fpm

15. Triple Flash 150 FPM -----------------

Three Pulses per flash @ 150 fpm

16. Double Flash 150 FPM---------------Two Pulses per flash @ 150 fpm

17. Single Flash 150 FPM----------------One Pulse per flash @ 150 fpm

18. Single Flash 250 FPM----------------One Pulse per flash @ 250 fpm

19. Single Flash 375 FPM------------------One Pulse per flash @ 375 fpm

0

0

1

1

2

9

9

9

9

2

1

LOC

LOC

LOC

9

9

9

9

1

2

1

2

3

Located on front of

Integrated PCB/Light Engine

Momentarily short and

release to change patterns

Optic removed for clarity

The flash pattern can be changed by shorting the J4 pad with a wire or blade of

a screwdriver (shown below). The lighthead can be reset to the default by short-

ing the J4 pad for greater than 5 seconds and then releasing

The following table shows the functions of the conductors of the 7 conductor cable. Please note that the CC

must be powered (red conductor must have +12VDC) before any of the functions can be enabled. The blue,

orange, and yellow flash activation conductors, when energized, enable the lightheads to be flashed.

Note: All control inputs are +power enabled.

Control Input Function Definition
Wire Color

Function

Description

BLUE (primary)

Flash Activation

Energizes light heads per the pattern chosen by the

end user or, if left unchanged, per the defaults set at the

factory (see table of flash patterns).

ORANGE (secondary)
YELLOW (multi-color)
WHITE

Dimming

Dims lighthead modules

GREEN

Pattern Select

Light Bar Flash Pattern Select Wire & Diagnostic Test

BLACK

Ground

Ground

RED

Power

+12V Input Supply

PriZm II

TM

, Torus

TM

, and TriCore

TM

modules with Central Controller

Advertising