EFCO S5900 Inside Glazed User Manual

Page 14

Advertising
background image

EFCO CORPORATION 6/2012 PART NO. Y352

Page 14 of 18

Series 5900 Inside Glazed Curtain Wall Installation Instructions

5.) Seal all corners. Pull the horizontal gaskets, seal the ends with sealant, and

jam into the vertical gasket to insure a snug fit as shown in FIG. 3 above.

Section IX: Glazing

Glazing

C.)

Position and install the setting blocks and shallow pocket jamb spacers per the
“APPROVED” shop drawings.

D.)

Install infill; typical edge bite is ½”.

1.) Hold infill above the sill horizontal and load the jamb side into the deep

pocket. Rotate the opposite side of the infill into the shallow pocket, and

position infill into the opening. Set the infill squarely onto the setting blocks
with the exterior face of the infill pushed up against the exterior gasket.

Take care not to roll the exterior gasket out of the race.

2.) Install the interior wedge in short lengths to 3 edges of the infill to hold

temporarily.

3.) Install the glazing bead at the head. NOTE: Seal along the face of the mullion

prior to installation of the glazing bead to provide a weather tight seal. Tool
and clean excess sealant from the exposed surfaces after the bead is

positioned as shown in FIG. 4.

4.) Install the jamb spacers as shown in FIG. 5 on page #15.


Setting block

Interior dense wedge gasket

Exterior preset gasket

Sealant

Customer / Installer Note:
EFCO setting blocks are
typically 4” in length with
different depths. If the
glazing infill is “NOT BY
EFCO” and glazing sizes are
larger than 40 square feet,
then the glazing details
must be reviewed by the
glazing manufacturer for

proper setting block size.

Advertising