EFCO S5900 Inside Glazed User Manual

Page 15

Advertising
background image

EFCO CORPORATION 6/2012 PART NO. Y352

Page 15 of 18

Series 5900 Inside Glazed Curtain Wall Installation Instructions

FIG. 4

Section IX: Glazing

Glazing

FIG. 5

5.) Remove the temporary glazing wedges and install the interior wedge. Cut the

gasket the same as noted in page #13.

6.) Gaskets with factory molded (Vulcanized) corners are optional.

If molded corners are used, installation should be as follows:

a.) Start at the top and bottom corners and work to the center.

Make sure the corners are square and true, and that full

engagement of the gasket is achieved. The gasket should
be slightly larger requiring some “crowding”. Gaskets should

NEVER BE STRETCHED TO FIT.






Floor line

Ceiling

horizontal

Stool horizontal

Molded Corners

Tape the top of the

gasket assembly to

the mullion face

when using Molded

Corner gaskets.

“W” type jamb spacer

at shallow pocket

1” Infill

“W” type jamb spacer

at deep pocket

“W” type jamb spacer block at

centerline of D.L.O. height

“W” type jamb spacer block at

centerline of D.L.O. height

¼” Infill

Advertising