Door frame installation, E) 1/4" & 1/2" glazing adaptors w/ l129 deflector, C) l126 water deflector for 1" glazing – EFCO 960 Series User Manual

Page 41: D) typical detail showing parts relationship, B) glass setting chair assembly, Fig. # 27a, Step 2) step 3) step 1), Fig. # 27

Advertising
background image

Conc. rod panic

K-153/K-154

& screws

Threshold clip

Threshold clip

& screws

K-124/K-125

NOTE:

FIG. # 27A

(9950 Typ.)

THRESHOLD

Also see Fig. # 28 thru Fig. # 30 on page 40.

NOTE: If NO entrance frame is required, proceed to Section VII.

NOTE: If an entrance frame is required, it must be installed first.

Anchor the door frame as indicated below in Fig. # 27A.

Set the assembled door frame in the opening, plumb and level.

Correctly locate the entrance frame in the opening.

STEP 2)

STEP 3)

STEP 1)

PAGE 39

JDA 3/2002

SECTION VI - DOOR FRAME INSTALLATION

WEEP THE TRANSOM BAR WITH (2) 1/4" DIA. HOLES, 5/8" DOWN

FROM THE TOP AND AT 1/4 POINTS.

#9633 SHOWN,
OTHERS SIMILAR.

JAMB

END

FIG. # 27

960 Wall

1/4" DIA.

.625

1/4 POINT

The door jambs run
to the floor and are
cut longer than other
verticals.

This continuous bead

of sealant runs from

jamb to opposite jamb,

under the threshold and

to the condition or it ties

into the perimeter seal
under the side lite sill

flashing.

Advertising