Drain installation and connection – Environmental Water Systems RO4-UV User Manual

Page 10

Advertising
background image

10

www.ewswater.com O: 702.256.8182; M-F 8:30am-4:30pm PST E: [email protected]

Step 1

From the parts bag locate:

Drain saddle assembly and the 1/4” x quick connect fitting that is needed for the application

For use with a non-air gap installation: use (smaller) 1/4” quick connect fitting x 1/4” mpt

For use with an air gap installation:

use (larger)

3/8” quick connect fitting x 1/4” mpt

Step 2

Place the drain saddle but do not tighten.

Placement of drain saddle should be located on the vertical tail piece

of the plumbing system at least 2” above the horizontal outlet or trap assembly.

NOTE: On the vertical pipe:

The higher the placement on this pipe, the greater the chance of increased noise in your waste line. Drain

connection should be pointing out or towards you as you look into the cabinet.

On the horizontal pipe as an alternate location:

See illustration A, the drain saddle should be at a 10 o’clock or 2 o’clock position

Step 3

Once the drain saddle is placed, use a 1/4” drill bit, and drill a hole slightly above the drain saddle. Do not drill through

the other side of the pipe. Make sure the one hole is complete with clean edges and clear of debris.

WARNING:

IF DRILLING METAL PIPE, PROTECT YOURSELF FROM SERIOUS INJURY OR FATAL SHOCK, USE A HAND DRILL

OR A CORDLESS DRILL TO MAKE THE HOLE. IF YOU USE AN ELECTRIC DRILL, OUTLET MUST BE GROUNDED.

USE SAFETY GLASSES OR OTHER EYE PROTECTION WHEN GRINDING TO PREVENT POSSIBLE EYE INJURY

DUE TO FLYING PARTICLES.

Step 4

Loosen drain saddle and slide over the 1/4” hole. Make sure the hole in the drain pipe is aligned with the hole in the

drain saddle. Tighten drain saddle using a screwdriver, alternating sides for even tightening.

Step 5

Using Teflon tape (not included) wrap 1/4” male threads on 1/4” x quick connect fitting (selected for air gap or non-air

gap application) using clockwise motion for at least three revolutions. Hand tighten fitting clockwise into drain saddle.

Caution:

Do Not Overtighten.

When installing drain saddle on a

horizontal pipe (thats’ the one that goes

across shown in dark)

Install connection at the 10 o’clock or 2

o’clock position (as illustrated to the left)

This allows for the proper flow of RO

drain rejection water and will help to

prevent any cross-contamination.

WARNING:

Avoid mount off the garbage disposal

drain pipes.

Drain Installation and Connection

Using two sinks?

Mount drain saddle

at either location

(shown in dark)

disposal

trap

sink #1

sink #2

strictly for illustration purposes only

Illustration

A

Using one sink?

Mount

drain saddle

here

Note: horizontal pipe

see Illustration A

10 o’clock position

on horizontal pipe

2 o’clock position

on horizontal pipe