Supplied professional connection, Professional installation is strongly recommended – Environmental Water Systems RO4-UV User Manual

Page 7

Advertising
background image

7

www.ewswater.com O: 702.256.8182; M-F 8:30am-4:30pm PST E: [email protected]

*Even though this connection can be used in over 90% of household applications, EWS, Inc. can not anticipate all the different locations, applications and

materials used by your builder and/or plumbing contractor or any pre-existing situations regarding your household or sink piping and cannot be responsible

for additional parts that may be necessary. Proper connection should meet all local codes. If necessary contact a qualified licensed plumber for another

part or method to properly install this system.

Instructions from the bag containing the supplied connection

From parts bag locate: Angle Stop Valve

5 feet of red or orange 1/4” tubing (the proper tubing from the water supply to the system)

Step 1

BEST METHOD: Shut off the main water supply to the house and open the kitchen faucet to

relieve water pressure in the hard pipe. Once water stops flowing from the kitchen faucet, shut off

the water supply at brass or chrome supply valve. This is the shut off valve for the cold water side

of the faucet under the sink (see illustration)
NOTE: Shutting the angle stop only, still leaves water in that pipe.
Step 2

Disconnect riser from brass or chrome supply valve.

This is the cold water line that feeds your existing kitchen faucet.
Step 3

Ensure that the sealing gasket is fully seated into the angle stop valve female thread.
Step 4

Install angle stop valve on supply valve.
Step 5

Connect the riser to the angle stop valve.
Step 6

Fully insert tubing into the quick connect fitting on the side of the angle stop valve.

CAUTION: USE ONLY COLD WATER LINE. NOT INTENDED FOR SUPPLY BY HOT WATER.

After complete installation of the system, open main water supply to the house and open all valves

and check for any leaks.

If needed, please refer to the John Guest Speedfit Installation Guide and Technical Check List

for all other information or visit their website @ www.johnguest.com

Angle Stop Valve (ASVPP1LF)

NSF 51 Compliant

LEAD FREE - Meets AB1953

Supplied Professional Connection

Professional Installation is Strongly Recommended

The supplied fitting is a John Guest Angle Stop Valve

which connects between the supply valve and riser to the main water supply line*.

Pictured:

Example of shut off

valve and riser up to

the cold side of the

kitchen faucet typically

found under the sink

Pictured:

Example of shut off

valve and riser up to

the cold side of the

kitchen faucet with the

properly installed angle

stop valve

riser to cold side of the

kitchen faucet

tubing to

system

shut off to

water

system

To Insert: Make sure tubing has

an even edge than press tubing in

firmly and completely

Never Pull Tube Out To Remove

Push Collet In To Release

To Test Fitting:

Give a Gentle “Tug” To Insure

Proper Connection

See All

Cautions, Warnings and Inspections

Advertising