Five-stage reverse osmosis – Environmental Water Systems 5 Stage Reverse Osmosis Systems User Manual

Page 31

Advertising
background image

31

www.ewswater.com O: 702.256.8182; M-F 8:30am-4:30pm PST E: [email protected]

Path of Water Flow through System

from inlet water supply

1

through Sediment (PRESED-05)

1a

through Booster Pump (if applicable)

2

through Prefilter (RO-F-GAC-500) then

3

through Membrane (RO-M-TFC) then

3a

through UV Module (if applicable)
into Storage Tank until needed

When water is needed

water flows from Storage Tank

4

through Postfilter (RO-F-INLINE) then

5

through 2nd Postfilter (GAC-00) then
through dispenser or into another
device (if applicable)

94

91

93

92

95

95

Five-Stage Reverse Osmosis

Schematic, Parts: Shown with Booster Pump Option
for illustration purposes only

Optional: UV Disinfection Moduleshown below

5, 6

7

4

3

3

8

10

9

12

14

32

13

Optional:

Booster Pump

24

18

1

29

28

30

31

28

3

28

13

9

9

9

9

9

Ref. No.

1
3
4
5
6
7
8
9

10

10a

12
13
14
18
24
25
28
29
30
31
32

20
21
22
23

2

15

11

19

16
17
26
27
---

Option

91
92
93
94
95

---
31

Part No.
h-membrane
h-filter
PRESED-05
fc-rsr-wh
fc-rsr-gy
fc-ro-svl-t
CI480821W
CI480822W
ro-brkt-5
ro-brkt-5-bp
PI480821S
h-m-clip
RO-M-TFC
ro-rsr-tfc
GAC-00
PI010822S
h-f-o-ring
020-MVH-0
RO-F-INLINE
PPC212W
RO-F-GAC-500

Not Shown
t-blk-drain
t-blue
t-orange
t-yellow

Not Shown
ro-tank 03.2
ro-tank valve
Not Shown
ro-clamp kit
Not Shown
STV-2
Not Shown
fd-ch-wh
fd-ag-wh
PI011222S
t-blk-gap
WRENCH

See Above
H-UV
n/a
n/a
UV-LAMP
fc-uv-jaco
Not Shown
POU-UV-E68
PPC212W

Description
M/H; STRAIGHT PORT
#10 SL WHITE/WHITE WO/PR
PX05-9 7/8" 5M SED CARTRIDGE
JG 1/4" X 1/8" M COMM - White on RSR
JG 1/4" X 1/8" CONN - Grey on RSR
JG 1/4" SWIVEL BRANCH T
JG 1/4" X 1/8" FIXED ELBOW; WHITE
JG 1/4" X 1/4" FIXED ELBOW; WHITE
.090 ALUM BRACKET; POWDER COAT
Substitute bracket with Booster Pump option
JG 1/4" X 1/8" FIXED ELB
WHITE 2" FAST CLIP PPC202W
TFC MEMBRANE
150 GPD RSR FLOW CONTROL RSR100-150
10" GAC CARTRIDGE
1/4" X 1/4" MALE CONNECTOR
HOUSING O-RING FH4000
O-RING KIT
10" T40 CARBON INLINE; 1/4" FNPT
DOUBLE CLIP - WHITE
HIGH-DENSITY GAC PREFILTER

See Tubing Connections, Pg. 13-14
1/4" PE TUBING; 60"; BK-P, DRAIN
1/4" PE TUBING; 60"; BL-P, OUTPUT
1/4" PE TUBING; 60"; OR-P, INPUT
1/4" PE TUBING; 60"; YL-P, TANK

See Storage Tank, Pg. 11
RO102W 3.2 GALLON TANK 141S152
1/4" FQC X 1/4" FPT EL-VALVE PPSV500822W
See Drain, Pg 12
DRAIN CONNECTOR; 1/4" FPT PDC602F
See Inlet Water Connections, Pgs 8-9
SELF PIERCING SADDLE VALVE
See Dispenser/Faucet, Pgs. 4-7
LONG REACH FAUCET; WH/WH QMP-102W
AIR GAP FAUCET ADAPTER
3/8" X 1/4" MALE CONECTOR-Air Gap Kit
3/8" PE TUBING BLACK - Air Gap Kit
SPANNER WRENCH FOR FILTER HOUSINGS

UV Disinfection Module Shown Separately
FULLY ASSEMBLED MODULE ON TOP OF UNIT
UV MODULE HOUSING
UV CAP, O-RING AND GLASS SLEEVE
UV LAMP AND LAMP CORD
JACO 1/4"COMPRESSION X 3/8" FIXED ELBOW

UV ELECTRIC 24 V TRANSFORMER
DOUBLE CLIP - WHITE

9

illustrated quick

connect fitting

and proper tubing

connection

8

31 Double Clips not shown with this UV illustration

Advertising