HAND CONTROL UNIT
To connect the Hand Control Unit (HCU), remove the connector
cap on the motor base. This connector is located adjacent to the
fiber optic connectors on the side panel. Plug the cable connector
from the HCU into the receptacle on the front panel of the Motor
Base Unit and turn until tightened. The HCU is now ready to
operate. Be sure to coordinate the use of the HCU with the
operation of the Model 2090 Positioning Controller.
To allow the HCU to operate, push the control switch from MAIN
to HAND. When in the HAND position, the Model 2090
Positioning Controller is overridden until control is returned by
the HCU. If the Model 2090 Positioning Controller is left on
while the HCU is used, all position changes are recorded by the
Model 2090 Positioning Controller.
CAUTION
Do not plug the Hand Control Unit into the motor
base while the Motor Base Unit is operational. Coordinate with
the operator of the Model 2090 Positioning Controller before
plugging in, using or unplugging the Hand Control Unit. Do not
push the CW and CCW buttons simultaneously. Be sure that the
motor has come to a complete STOP before reversing direction.
When you are ready to return control back to the Model 2090
Positioning Controller, toggle the control switch from HAND to
MAIN.