5 example using os-9 development system, 6 example using hyperterminal from windows 95® o, Bootstrap loader – Kontron Bootstrap Loader User Manual

Page 16: 6 example using hyperterminal from windows 95, Or windows nt

Advertising
background image

Bootstrap Loader

Page 10

© PEP Modular Computers

2/98

Note: The maximum size of the binary module which can be loaded or updated is 256 Kbytes. If a module greater than 256
kBytes is sent to the Bootstrap Loader each S-record which exceeds this size will be refused. As a result the loaded module
is declined due to an invalid CRC value.
Note: If only one module is in the FLASH, this module cannot be updated.
Note: Loading or updating modules from an absolute memory address is not supported.

3.5 Example using OS-9 development system

The host is assumed to be an OS-9 development system. A serial cable is used to connect the ser0 port of the board to
program to t0 of the development system. The serial connection should run at 38400 baud. The following steps must be
performed to update the 'sysgo' module:

Host:
xmode /t0 baud=38400 nopause
iniz /t0

Target:
pf ser0 38400
Idmod -u

Host:
binex -s=3 sysgo >/t0

3.6 Example using Hyperterminal from Windows 95

®

or Windows NT

®

See 'Example using Hyperterminal from Windows 95

®

or Windows NT

®

'

on page 6 point 2.11.