1 ipmb-l link sensor, 3 field replaceable unit (fru) information, Field replaceable unit (fru) information – Kontron RTM806x User Manual

Page 24: Table 2-3 board information area

Advertising
background image

11

RTM806X

www.kontron.com

X

Exceed critical threshold / Error Assertion

*

Power On/Off

-

Power On

N

No change

2.7.2.1

IPMB-L Link Sensor

The RTM806X has an IPMB-L link to communicate with the processor board and other devices in the chassis
chassis IPMB-0 bus. MMC monitors the bus for any link failure and sends the bus failure event to the front
board upon the recovery occurs.

2.7.3

Field Replaceable Unit (FRU) Information

The FRU Information provides inventory data about the boards where the FRU Information Device is located.
The part number or version number can be read through software.

FRU information in the RTM806X includes data describing the RTM806X board similar to AMC.0 R2.0
specification requirements. This information is retrieved by the RTM, enabling reporting of board-specific
information through a standardized mechanism.

Table 2-3:Board Information Area

25

Power Good

Actual RTM power good status

-

X

26

Pwr Good HD1

Actual HD1 power good status

-

X

27

Pwr Good HD2

Actual HD1 power good status

-

X

28

Health Error

General health status

*

N

Board Information Area

Field Description

Value (hex)

Format Version

0x01

Board Area Length

*Calculated

Language code

0x00

Manufacturing Date / Time

*Based on mfg. date

Board Manufacturer type/length

*Calculated

Board Manufacturer

“Kontron”

Board Product Name type/length

*Calculated

Board Product Name

“RTM806X”

Board Serial Number type/length

*Calculated

Board Serial Number

Manufacturer S/N

Board Part Number type/length

*Calculated

Board Customer Part Number

"T5707###_R"

FRU File ID type/length

*Calculated

IPMI
sensor
ID

Sensor Name

Description (Sensor Type, Event trigger)

Scanning En-
abled under
Power State

Health LED
(Green to Am-
ber)