3. Hot Swap and Installation

3.1

RTM Hot Swap and Installation

Because of the high-density pinout of the hard-metric connector, some precautions must be taken when
connecting or disconnecting a RTM to/from an AT8060:

1- Rail guides must be installed on the enclosure to slide the RTM to the AT8060.

2- Do not force the RTM if there is mechanical resistance while inserting it.

3- Screw the faceplate to the enclosure to firmly attach the RTM to its enclosure.

4- Use extractor handles to disconnect and extract the RTM from its enclosure.

3.1.1

Installing the RTM in the chassis

To install the RTM:

1- Remove the filler panel of the slot.

2- Ensure the RTM is configured properly.

3- Carefully align the PCB edges at the bottom and top card guide.

4- Insert the RTM in the system until it makes contact with the CPU board.

5- Using the ejector handles, engage the RTM in the CPU board connectors until the ejectors are

locked.

6- Fasten screws at the top and bottom of the faceplate.

3.1.2

Removing the RTM from the chassis

To remove the RTM:

1- Unscrew the top and the bottom screw of the faceplate.

2- Unlock the upper handle latch.

3- Wait until the blue LED is fully ON, this mean that the hot swap sequence is ready for RTM removal.

4- Use the ejector to disengage the RTM from the CPU board.

5- Pull the RTM out of the chassis.

WARNING

Always use a grounding wrist wrap before installing or removing the board from a
chassis.