Connecting a flat panel, 2 fan connector, Fan connector – Kontron KTT30-mITX User Manual

Page 23

Advertising
background image

KTD-N0857-A

Page 20

Pin Connectors



KTT30/mITX Users Guide

!

Warning: Do not mix the Fan Connector and the ccTalk connector. If mounting Fan into ccTalk
connector Fan might be damaged.

Note: The backlight adjust signal uses the Pulse Width Modulation (PWM) technique.

A proto- type cable

with open ends is shippable from KONTRON (part number 821515).

Note:

1)

To protect the external power lines of peripheral devices make sure that

- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.

Warning: Check the U-Boot Setup for correct settings for your panel – not doing so might cause permanent damage to your panel.

Connecting a Flat Panel

Check if you have the correct panel cable. Inspect the cable for damages.

Switch on the power supply and activate/save the desired settings with help of the U-Boot
bootloader (for further details see the 'Software Guide' chapter 'U-Boot Setup'). Switch off
the power supply.

Connect an external power supply for the correct backlight voltage (except the power supply
complies with the backlight voltage).

Connect the cable to the flat panel connector J1 on the KTT30 and connect the other end to
your display.

Switch on the power supply. If you only see a blank screen contact your distributor for tech-
nical support.

8.2

Fan Connector

For an optional fan use the connector J15 (4 pins). The interface only supports +5V fans and operates with
a PWM output (Control) which allows the control of fan speed.

Header

Pin

Signal

Description

Type

1

Control

PWM output

O-5.0

2

Sence

Tacho signal (open drain)

I

3

VCC5

1)

Power +5V

PWR

4

GND

Ground

PWR


Note:

1)

To protect the external power lines of peripheral devices make sure that

- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.




Advertising