8 environmental specification, 1 temperature specification, 2 humidity – Kontron COMe-bSC6 User Manual

Page 22: Environmental specification, Temperature specification, Humidity

Advertising
background image

COMe-bSC6 / Product Specification

3.8

Environmental Specification

3.8.1

Temperature Specification

Kontron defines following temperature grades for Computer-on-Modules in general. Please see chapter 'Product
Specification' for available temperature grades for the COMe-bSC6

Temperature Specification

Operating

Non-operating

Validated Input Voltage

Commercial grade

0°C to +60°C

-30°C to +85°C

VCC: 8.5V - 18V (20V@nonECC)

Extended Temperature (E1)

-25°C to +75°C

-30°C to +85°C

VCC: 12V

Industrial grade by

Screening (XT)

-40°C to +85°C

-40°C to +85°C

VCC: 12V

Industrial grade by

Design (E2)

-40°C to +85°C

-40°C to +85°C

VCC: 8.5V - 18V (20V@nonECC)

Operating with Kontron heatspreader plate assembly

The operating temperature defines two requirements:

» the maximum ambient temperature with ambient being the air surrounding the module.

» the maximum measurable temperature on any spot on the heatspreader's surface

Test specification:

Temperature Grade

Validation requirements

Commercial grade

at 60°C HSP temperature the CPU @ 100% load needs to run at nominal frequency

Extended Temperature (E1)

at 75°C HSP temperature the CPU @ 75% load is allowed to start speedstepping for thermal protection

Industrial grade by

Screening (XT)

at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection

Industrial grade by

Design (E2)

at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection


Operating without Kontron heatspreader plate assembly

The operating temperature is the maximum measurable temperature on any spot on the module's surface.

3.8.2

Humidity

» 93% relative Humidity at 40°C, non-condensing (according to IEC 60068-2-78)

22

Advertising