Thermal Configuration

Feature

Options

Description

Critical Trip Point

POR

15°C


119°C

This value controls the temperature of the ACPI Critical
Trip Point - the point in which the OS will shut the

system off. Note: 100°C is the Plan Of Record (POR) for
all Intel mobile processors

ActTPnt Low Temp

Disabled

15°C
..
55°C

95°C

This value controls the temperature of the ACPI Active

Trip Point - the point in which the OS will turn the
processor fan on Active Trip Point Low Fan Speed.

ActTPoint Low Fan Speed

70

Active Trip Point Low Fan Speed in percentage. Value
must be between 33% - 100%. This is the speed at

which fan will run when Active Trip Point Low is crossed.

Active Trip Point High

Disabled
15°C


79°C


95°C

This value controls the temperature of the ACPI Active
High Trip Point - the point in which the OS will turn the

processor fan on Active Trip Point High Fan Speed.

Passive Trip Point

Disabled

15°C

95°C

119°C

This value controls the temperature of the ACPI Passive

Trip Point - the point in which the OS will begin
throttling the processor

- Passive TC1 Value

1

This value sets the TC1 value for the ACPI Passive
Cooling Formula. Range 1 - 16

- Passive TC2 Value

5

This value sets the TC2 value for the ACPI Passive

Cooling Formula. Range 1 - 16

- Passive TSP Value

10

This item sets the TSP value for the ACPI Passive Cooling
Formula. It represents in tenth of a second how often

the OS will read the temperature when passive cooling
is enabled. Range 2 - 32