RID 24139 PD13, Rev. 01

Page 8

PD13: CP3-SVE-M76AC

CPCI Power Supply

Output Power Diagrams

Figure 5: Signal when Switched On

Protection and Control

Environment

Overvoltage protection

125 %

±

5 % for V1, V2

Overload protection

Current limitation: >150 % I

Rated

for V

1

, V

2

Thermal shutdown with auto-restart for V

3

Output permanent short-circuit proof

Over temperature protection

Switches off if inside temperature becomes too high,
restart with hysteresis

Operating ambient temperature

0 °C to + 55 °C (without derating)
0 °C to + 70 °C (with derating)

Derating

2.0 % / °K between 55 °C and 70 °C

Climatic humidity

93 % RH at 40 °C, non-condensing
(acc. to IEC 60068-2-78)

Recommended airflow

≥ 0.5 m/s