RID 24139 PD13, Rev. 01
Page 8
PD13: CP3-SVE-M76AC
CPCI Power Supply
Output Power Diagrams
Figure 5: Signal when Switched On
Protection and Control
Environment
Overvoltage protection
125 %
±
5 % for V1, V2
Overload protection
Current limitation: >150 % I
Rated
for V
1
, V
2
Thermal shutdown with auto-restart for V
3
Output permanent short-circuit proof
Over temperature protection
Switches off if inside temperature becomes too high,
restart with hysteresis
Operating ambient temperature
0 °C to + 55 °C (without derating)
0 °C to + 70 °C (with derating)
Derating
2.0 % / °K between 55 °C and 70 °C
Climatic humidity
93 % RH at 40 °C, non-condensing
(acc. to IEC 60068-2-78)
Recommended airflow
≥ 0.5 m/s
+5V
+3.3V
voltage: 1V / div
.
time: 0.5 ms / div.