6 auxiliary connectors and signals (optional), Optional system configurations, 1 power supply options – Kontron CP-ADAP-P47-PB (6U) User Manual

Page 10

Advertising
background image

PD17: CP-ADAP-P47-PB (6U)

CPCI Backplane

Page 10

© 2003 PEP Modular Computers GmbH

RID 24229 PD17, Rev. 01

4.6

Auxiliary Connectors and Signals (Optional)

There are two, two-contact, male auxiliary connectors, JP16 and JP17, optionally available on
this backplane.

JP16 and JP17 make the signal lines, PRST and INH# respectively, available for external
switches to either invoke a system reset or to switch the power supply on or off.

Orientation and Pinouts of CP6-BP8-P47-STD Connectors JP16 and JP17

5.

Optional System Configurations

5.1

Power Supply Options

The design of this power distribution backplane allows for several different power supply op-
tions:

1. The default configuration of a single compatible pluggable power supply, installed either

in the upper or lower PS bay.

2. Addition of a compatible power supply installed in the upper/lower PS bay as required.

3. Addition of compatible power distribution backplanes installed either to the left or right of

the backplane as required.

Option 1 is the standard configuration which is delivered with a 47-contact female Positronic
type power supply connector.

Option 2 requires the installation of an additional compatible power supply in the appropriate
PS bay.

Option 3 requires the installation of additional power distribution backplanes as required to sup-
port the application requirements. As in option 2, compatible power supplies are required.

1

2

JP17 JP16

Table 9: Pinouts of CP6-BP8-P47-STD
Connectors JP16 and JP17

Pin

Function

JP16

1

GND

2

PRST

JP17

1

GND

2

INH#

Advertising