5.5

System Monitor and Control Connectors JP11 and JP12

This backplane is provided with two connectors for system monitor and control signal interfac-
ing to external devices. Both are 26-contact, male, double pin-row connectors, and have the
same signal pinout configuration. The system management bus (IPMB0), the power supply
monitor and control signals, and push button reset (PRST#) signal are all implemented on
these connectors.

Figure 6: Orientation and Pinout of the SMC Connectors JP11 and JP12

Note...

The signal pinout assignment is a function of the power supply actually utilized
with this backplane. Refer to the corresponding power supply documentation for
the applicable signal pinout.

1

13

b
a

JP12

1

13

b
a

JP11

Table 6: Pinout of SMC Connectors
JP11 and JP12

Pin

Function

Pin Row A

Pin Row B

1

IMPB0_SCL

GND

2

IMPB0_SDA

IMPB0_PWR

3

N/C

GND

4

N/C

GND

5

N/C

GND

6

INH#

GND

7

FAL#

DEG#

8

PRST#

GND

9

GND

V1 SENSE (+5V)

10

V2 SENSE (+3.3V)

SENSE RTN

11

V3 SENSE (+12V)

GND

12

V1 SHARE (+5V)

V2 SHARE (+3.3V)

13

V3 SHARE (+12V)

GND