Troubleshooting—TIGW1U server

In addition to the beep codes above, additional beep codes are provided if an Intel

®

Remote Management Module (Intel

®

RMM) is installed. The RMM provides the following

additional beep codes.

Table 10.

POST Error Beep Codes

Number of Beeps

Reason for the beeps and action to take

1, 2, or 3

Memory error. Reseat the memory or replace the DIMMs with known good modules.

4 – 7 or 9 – 11

Fatal error indicating a possible serious system problem. Remove all add-in cards and

re-start the system. If the error still occurs, contact your system manufacturer. If the

beep codes are not generated after the add-in cards are removed, insert the cards one

at a time, booting the system between each card addition, until the beeps again occur

to reveal the malfunctioning card.

8

Replace or reseat the system video add-in card. If on-board video is bing used, the

server board may be faulty.

Table 11.

Error Beep Codes Provided by an Intel

®

Remote Management Module 2

Beep Code

Reason for the beeps and action to take

1

Control panel CMOS clear has been initiated.

1-5-1-1

Processor failure. Reseat or replace the failed processor.

1-5-2-1

No processor is installed or the CPU 1 socket is empty. Reseat or replace the failed

processor.

1-5-2-3

Processor configuration error or CPU 1 socket is empty. Reseat or replace the failed

processor. In a two-processor system, make sure the processors are identical.

1-5-2-4

Front-side bus select configuration error.

1-5-4-2

DC power unexpectedly lost.

1-5-4-3

Chipset control failure.

1-5-4-4

Power control failure.