Mercedes-Benz SLK-Class 2006 Owners Manual User Manual
Page 426
425
Practical hints
Jump starting
̈
Make sure the two vehicles do not
touch.
̈
Turn off all electrical consumers.
̈
Apply parking brake.
̈
Shift gear selector lever* to position P
(manual transmission to Neutral).
̈
Open the hood (
̈
Flip up cover from positive under hood
terminal
1 Positive terminal of charged battery
2 Positive under hood terminal in front of
water tray
3 Negative under hood terminal in front
of water tray
4 Negative terminal of charged battery
̈
Connect positive terminal
1 of the
charged battery with positive under
hood terminal
2 in front of the water
tray with one jumper cable. Clamp the
cable to positive terminal
1 of the
charged battery first.
̈
Start the engine of the vehicle with the
charged battery and run at idle speed.
̈
Connect negative terminal
4 of the
charged battery with negative under
hood terminal
3 in front of the water
tray with the second jumper cable.
Clamp the cable to negative
terminal
4 of the charged battery
first.
̈
Start the engine of the disabled vehi-
cle.
You can now turn on the electrical con-
sumers. Do not turn on the lights under
any circumstances.
̈
Remove the jumper cables first from
negative terminals
3 and 4 and then
from positive terminals
2 and 1.
You can now turn on the lights.
̈
Have the battery checked at the near-
est authorized Mercedes-Benz Center.
Warning!
G
Keep flames or sparks away from battery.
Do not smoke.
Observe all safety instructions and precau-
tions when handling automotive batteries
!
Never invert the terminal connections.
i
Vehicles with automatic transmission*: