General Description

BENEFITS

• Safety: air flow is maintained at required speed at

all sash heights

• Energy savings: only the lowest required amount of

air is exhausted therefore reducing energy bill

• User comfort: Low air speeds ensure comfortable

noise level

• Ease of installation and maintenance
• Stable and accurate analogical sensor reading
• Attractive design: available in choice of LED or

digital display

RANGE

Versions:

C LED: Monitors and controls air speed, LED lights
C DIGITAL: Monitors and controls air speed, digital

read out in meter per second or feet per minute

FEATURES

• Audio and visual alarm
• 0 to 10V or 4-20mA VAV system to link to inverter
• 3 Pushbuttons: Fan On/Off, Light On/Off, Mute
• Automatic pre-purge with inverter
• 30s purge following fan switch off
• Alarm disabled when fan switch off
• Sash High indicator
• Auxiliary contact for fan make up, etc.

OPTIONS

Surface Box Mounting: Plastic enclosure to mount

the face plate and to avoid profile cutting the

service panel.
Alarm Relay: A remote alarm can be triggered from

a relay on the controller pcb.

Battery Back Up: Red LED alarm is still

functional up to 12 hours when unit loses power.
Custom Resin Stickers: Customizable resin

stickers with logo, address, etc.

COLORS

Plastic fascia is available in:

- White (Standard)

INTERNATIONAL STANDARDS

COMPLIANCE

In accordance with:
- European laboratory standard EN 14175-2
- Electromagnetic standards EN

61326 : 1997/A1 : 1998/A2 : 2001/A3 : 2003

(Test report RC-05-42060-1) US FCC Part 15

Class B edition 2005 (Test report RC-05-

42060-2-A)
- European RoHS directive governing disposal and

recycling of electronics

- French laboratory standard XPX 15203 of Sept. 1996
- CE

COMPONENTS

• Circuit Board: Panel mounted circuit board to

be installed vertically or horizontally onto fume

cupboard with 2x Ø 2.8 mm / 0.11" screws. IP55

protection ensured by “O” ring seal. Face plate to

be supplied with chemical resistant plastic sticker

(horizontal or vertical) with control/push buttons

on fascia. Surface box mounting optional.

• Numerical and Antistatic Sensor: To be installed

inside fume hood. Sensor measures air speed

variations inside fume hood. Supplied with a

3.5 m / 11.48' (5 m optional) shielded cable with

pin connections onto controller circuit board.
• Power Supply: 115 VAC to 12 VDC power

transformer directly into controller circuit board.

Comes with a wall plug and cord. Adaptor may be

required to fit local power socket.

PACKING

• Supplied in cardboard box which includes con-

troller circuit board, face plate, sensor and power
transformer. Surface box mounting optional.