R:02ser s:03ser confirm(enter) – ProgressiveRC 206B iCharger User Manual

Page 19

Advertising
background image


-19-

iCharger Synchronous Balance Charger/Discharger 206B

Charge-to-discharge & Discharge-to-charge cycle mode for a Lithium battery




























Lithium battery in monitoring mode

When you use other devices to charge or discharge Lithium pack, the iCharger can monitor each cell‘s
voltage, battery temperature, charge time and so on, if one of the batteries appears over-charged,
over-discharged, over-hot, over-capacity or over-time ,the iCharger will alarm with noise “Di…..” and blink
the raleted information.


















Note: when in Li monitor Mode, no need connecting the main port if connecting the balance port.

Charging/discharging cycle mode of Lithium battery.
The left side of the first line sets the type of battery (LiPo, Lilo or LiFe) and
the right side shows the cycle number. The second line shows the cycle
direction you selected: (C: x.xxV->D: x.xxV) or (D: x.xxV->C: x.xxV), the
value of the second line sets the final charge/discharge voltage. Press
Start/Enter button for more than 3 seconds with a sound ‖Di‖ to start the
next process.

Cycle number: 1 – 999

(only last 10 times cycle information will be

displayed)

Voltage: LiPo (3.00 – 4.20V), Lilo (2.50 – 4.10V), LiFe (2.00 – 3.60V)


The number of cells you set and the processor detects. If the checking
result is the same, it would enter to the next interface; if not the same, the
left side of the first line ‘R: xxSER‘ shows the number of cells detected by
the iCharger and the right side of the first line ‘S:xxSER‘ is the number of
cells set by the user. You should make sure that the configured number and
the actual number for the battery are the same and then you can start
charging by pressing Start/Enter. If not, press Batt type/Stop to go back to
the previous screen and adjust the setting.

Charging/discharging cycle mode of Lithium battery.
In this process, you can stop the cycle at any time by pressing the Batt
type/Stop
button. In the process of C>D or D>C, the blink ―C‖ indicates
charging, while ―D‖ indicates discharging. Press Inc button to display
each cell‘s voltage and its past cycling current (see the balance voltage
information& cycling information) and press Dec button to display the
General Status information.
During the waiting time of discharge-to-charge cycle mode, you can stop
the waiting process with pressing ―Start" button for three seconds!

LiPo MONITOR
3.0V 11.1V(3S)

Monitor mode of Lithium battery. The left side of the first line sets the type of
battery (LiPo, Lilo or LiFe). The value on the right side of the second line
sets the low limit of voltage and the battery pack number. After setting the
current and voltage press Start/Enter button for more than 3 seconds with
a sound ‖Di‖ to start the next process.

Individual alarm low-Vt: final discharging voltage to the highest
charging voltage (such as: LiPo 3.0V – 4.2V),
Battery series: 1 – 6 series




The monitor information, in this process; you can stop monitoring process at
any time by pressing Batt type/Stop button.
Press Inc button to display each cell‘s voltage (see the balance voltage
information), the iCharger will alarm with noise “Di….”when any errors
appear.

Start/Enter

>3 seconds

Batt type

stop

R:02SER S:03SER
CONFIRM(ENTER)

Start/Enter

Batt type

stop

Battery

Series

V-BP

Charge

Current

Li03 1.0A 12.60V
C>D 00993 59m:51

battery

voltage

number

of cells

Series

cycle

capacity

cycle

time

cycle

current

work

state

Start/Enter

>3 seconds

Batt type

stop

Battery

Series

V-BP

Charge

Current

Li03 50℃ 12.60V
Monitor 50m:43

battery

voltage

number

of cells

Series

run

time

Ext.

temperature

work

state

LiPo CYCLE 3
C:4.20V->D:3.00V

-

Dec

+

Inc

-

Dec

+

Inc

-

Dec

+

Inc

-

Dec

+

Inc

-

Dec

+

Inc

-

Dec

+

Inc

Advertising