Recommended connecting way – ProgressiveRC 206B iCharger User Manual

Page 6

Advertising
background image


-6-

iCharger Synchronous Balance Charger/Discharger 206B

Warnings and Safety notes

Keep the charger away from children and pets at all times.

Never leave the charger unsupervised when charging or discharging. If you leave, disconnect the battery

to prevent any unexpected dangers or damage.

Ensure the charger program and settings match the battery pack otherwise the battery will be damaged

and a dangerous situation may arise, especially for Lithium batteries, which may cause a fire.

Do not mix batteries of different types, different capacities or from different manufacturers.

Do not disassemble the charger.

Do not place the charger or any battery on a flammable surface or near a combustible material while in

use. Do not charge or discharge on a carpet, cluttered workbench, paper, plastic, vinyl, leather or wood,
inside an R/C model or inside a full-sized automobile.

Never block the air intake holes and never use in a refrigerated or high temperature environment. If used

in such an environment, the internal temperature protection may result in abnormal charging/discharging
that could be dangerous.

Do not allow water, moisture, metal wires or other conductive material into the charger.

Never charge or discharge any battery having evidence of leaking, expansion/swelling, damaged outer

cover or case, color-change or distortion.

Do not try to charge ―non-rechargeable‖ dry cells.

Do not exceed the battery manufacturer‘s suggested maximum charge rates.

Beware that the external case temperature of the charger will increase during charging/discharging at

high power.

Carefully follow the battery pack manufacturer‘s recommendations and safety advice.

Recommended connecting way:

1. Connect iCharger's input power supply, and turn on it.

2. Connect Li batteries' balance port

3. Connect the main charging port's positive pole to cells' positive pole, and then connect negative pole to
cells' negative pole (this will avoid striking fire while connecting Li cells).

4. Start charging and discharging...

5. After finishing charging and discharging, pls disconnect the cell and charger, and then turn off the charger's
power supply.


Standard battery parameters

LiPo

LiIo

LiFe

NiCd

NiMH

Pb

Nominal voltage

3.7 V/cell

3.6 V/cell

3.3 V/cell

1.20 V/cell 1.20 V/cell

2.0 V/cell

Max. charge voltage

4.2 V/cell

4.1 V/cell

3.6 V/cell

1.60 V/cell 1.60 V/cell 2.45 V/cell

Storage voltage

3.85 V/cell

3.75 V/cell

3.3 V/cell

n/a

n/a

n/a

Allowable fast charge
current

≤ 1C

≤ 1C

≤ 4C

1C –

2C

1C –

2C

≤ 0.4C

Min. discharge voltage
cut-off level

cut off level

≥ 3.0 V/cell ≥ 2.5 V/cell ≥ 2.0 V/cell ≥ 0.85V/cell ≥ 1.0 V/cell ≥ 1.75V/cell

Note: Be very careful to choose the correct voltage for different types of battery otherwise you may cause
damage to the batteries. Incorrect settings could cause the cells to vent, burn or explode leading to injury or
loss of property.