Cable connections and installation – Rice Lake 320IS Intrinsically-Safe Digital Weight Indicator - IS-6V Battery Pack Instruction Sheet User Manual

Page 2

Advertising
background image

2

IS-6V Battery Pack Installation Instruction Sheet

Cable Connections and Installation

The following section contains information on cable connections and installation for the

IS–6V Battery Pack

to a

320IS/320IS Plus

indicator.

NOTE: Intrinsically safe cables are specified by control drawing. All cables must meet the appropriate internal
inductance and capacitance according to the control drawing. Cable lengths are based on group classifications.

Figure 2. Cord Grip

Use the following procedure for connecting braided power cable:

1. Carefully remove 3" of insulation and 2 1/2" of braid from cable.

2. Remove domed cap and reducing gland from cord grip and place them on the cable. See Figure 2 above.

3. Remove domed cap and reducing gland from the parts kit. DO NOT confuse these with the parts

removed from the cord grip.

4. Transfer the metal piece of the reducing gland removed from the cord grip to the reducing gland from the

indicator parts kit.

5. Place the domed cap and reducing gland you removed from the indicator parts kit to the cable.

6. Install cable through cord grip stem, leaving braid outside of cord grip.

7. Lower reducing gland to edge of insulation and wrap braid over metal part of reducing gland.

8. Insert cable and reducing gland into cord grip stem.

9. Lower domed cap onto cord grip and tighten until a small swelling of the rubber between the domed cap

and the cable builds. See Figure 3 below.

Figure 3. Proper Cord Grip Compression

10. Wire cable to connector CN1. See Section 2.3.1 on page 6 of the

320IS

manual.

Table 1. DC Power Supply Connections

CN 1 Pin

Function

Color

1

+Voltage (5.8 – 7.9)

Green

2

Ground (V–, Common)

Brown

Stem

Reducing Gland

Domed Cap

Advertising