General, Unit inspection, Front panel – Carrier Access 52C User Manual

Page 2

Advertising
background image

2

GENERAL

Thank you for choosing Carrier! You can feel confident
in your selection because the same pride in craftsman-
ship and engineering knowledge that goes into Carrier
equipment at the Astrodome in Texas, the Sistine
Chapel in Rome, the US Capitol Hall of Congress, and
thousands of other installations worldwide has gone
into the construction of this unit.
The Carrier package terminal air conditioners and
heat pumps provide a high standard of quality in per-
formance, workmanship, durability and appearance as
they heat and cool the occupied air space year round.
This manual provides information for ease of installa-
tion, operation and maintenance of the 52C and 52P
units. The following units are covered in this manual
(see Figure 1 for additional unit information):
52CE 60 Hz cooling with electric heat units
52CQ 60 Hz cooling, electric heat, and heat pump units
52PE 60 Hz cooling with electric heat units
52PQ 60 Hz cooling, electric heat, and heat pump units
52PC 60 Hz cooling only units
All models are designed for through-the-wall installa-
tion. Separate installation instructions are included

with all accessory components. See Accessories section
on page 14 for complete listing of accessories.

UNIT INSPECTION

Examine unit for damage incurred during shipment.
File a claim immediately with the transit company if
damage is found.
The data information plate (Figure 1) lists the model
number, voltage ranges, and other important electrical
information about this product. Reading and under-
standing this material is important for proper use of
this unit. To access the information plate, the front
panel must be removed; see Figure 2.

FRONT PANEL

To remove the front panel:

1. Grasp panel firmly near bottom of both sides.
2. Pull panel forward then upward to release mag-

netic latches and partition hooks.

NOTE: Front panel may be secured to chassis with
2 screws located behind indoor air inlet filters. In order
to remove these screws, the filters must be removed
first. Refer to page 10 in this manual for instructions on
removing indoor air inlet filters.

Using Figures 1 and 3 as reference, verify that the
packaged terminal product ordered will operate prop-
erly in your facility. If you do not understand the in-
formation given or have questions about the product,
please call your local dealer or distributor.

Replacement Package Terminal Air Conditioner,
CLASSIFIED BY UNDERWRITERS LABORATO-
RIES INC., AS TO ELECTRIC
SHOCK, FIRE AND CASUALTY
HAZARDS ONLY. FOR FIELD
INSTALLATION WITH EXISTING
WALL SLEEVES, OUTDOOR LOU-
VERS, AND INDOOR PANELS AS
SPECIFIED ON THE PRODUCT.

IMPORTANT: The front panel has to be off the unit
to complete future checks and installation proce-
dures. Do not reinstall front panel at this time.

CANADIAN INSTALLATION

SERIAL 3701X11520

DATE OF MFG. 09/12/2001

VOLT RANGE 187-253

VOLTS 230/208

PH 1

MODEL 52PQA312301AA

HZ

60

MIN CKT AMPACITY 19.3

R-22 OZ 34

DESIGN PSIG 350 HIGH SIDE, 150 LOW SIDE

COOLING

HEATING

BTU/HR 12,100/12,000

AMPS 4.8/5.3

WATTS 1100/1100

EER 11.0/10.9

MOTOR

FAN

COMP

HP

FLA

RLA

LRA

6.1

29

0.75

1/8

BTU/HR 10,800/10,700

AMPS 15.6/14.5

WATTS 3570/2997

COP 3.2/3.2

HEATER

BTU/HR

AMPS 14.8/13.7

WATTS 3400/2850

WATER

STEAM

20

20

20

USE

TIME DELAY FUSE

OR HACR TYPE

CIRCUIT BREAKER

AMP

AMP

AMP

MAX FUSE

MAX BREAKER

FIGURE 1 — SAMPLE DATA INFORMATION PLATE

FIGURE 2 — REMOVING FRONT PANEL

Advertising