OPERATION

COMFORT CONTROLS

ADJUST AIRFLOW DIRECTION — The discharge

air grille is mounted on the front panel so that the air
discharges forward. If upward discharge is required,
remove the grille by removing screws on back of front
panel. Rotate grille 180 degrees and reinstall on the
front panel.

ADJUST VENT — The vent handle is on the left

side of the unit. Turn handle to open or close vent.
Vent will remain in last desired position until handle
is turned again. Magnet will ensure positive closure.
See Figure 13.

SETTING TEMPERATURE LIMITS — Setting tem-

perature limits on the unit provides the user a
restricted range of temperature control. See Figure 14.
NOTE: This adjustment is optional and is not applica-
ble to remote control units.

The temperature limits are factory set to full range,
which is 60 F to 90 F. To set restricted rotation of the
temperature control knob:

1. Remove front panel.
2. Remove temperature control knob to expose tem-

perature limiter.

3. Remove standoff pins from the 60 F and 90 F indi-

cator holes.

4. Replace standoff pin in hole for desired minimum

temperature.

5. Replace standoff pin in hole for desired maximum

temperature.

6. Reinstall temperature control knob.
7. Reinstall front panel.

NOTE: Temperature indicators stamped on tempera-
ture limiter are approximate and represent degrees F.

IMPORTANT: When unit is first started, high
humidity conditions can cause condensation to form
on discharge grille. Keep doors and windows closed.
Room humidity decreases and moisture evaporates.

80

85

90

60

65

70

75

TEMPERATURE
CONTROL
STANDOFF
PINS

FAN CYCLE
SWITCH

OUTDOOR
THERMOSTAT
(HEAT PUMP
UNITS ONLY)

CON

CYC

SET
SCREW

FIGURE 14 — OPERATING CONTROLS

VENT
DOOR

VENT
FILTER

MAGNET

OPEN

CLOSE

VENT HANDLE

FIGURE 13 — VENT DOOR