3 technical data, 1 miniflexlock pr 6011/30, Miniflexlock pr 6011/30 – Rice Lake Contego-Hygienic Weigh Module Kits, Top Cable Outlet User Manual
Page 6: Mounting kits pr 6011 installation manual
Advertising
Mounting Kits PR 6011
Installation Manual
EN-4
Sartorius
3 Technical Data
3.1
MiniFLEXLOCK PR 6011/30
PR 6011/30N
PR 6011/30S
Load cell max. capacity
500 kg…10 t
Permissible temperature range
-40 °C…+80 °C
Permissible horizontal force
5 kN
Perm. lifting force
Mounting bolts
Thread
size
M8
Rigidity
class
5.8
A2
Weight
net
5.00 kg
5.20 kg
with packing
5.35 kg
5.90 kg
Material
Steel, zinc-plated, chromated
and sealed (in compliance with
RoHS directive)
stainless steel 1.4301 acc. to
DIN EN 10088-3
Mounting aid
all dimensions in mm
Caution!
Remove the mounting aid after mounting!
Advertising