Explanation of Status LEDs’ Indication

























There are a total of 7 LED lamps in a row just below the 7-segment LEDs as shown in the above
figure. The label just below each LED is an abbreviation of their meaning.

The first LED from left to right is the Stable Status Indicator, this will be ON when the weight
display is stable.

The second LED from left to right is the Zero Status Indicator. This LED will be ON when the
weight display is within the Zero window range.


The third LED from left to right is the Net Mode Indicator, the indication of this LED

means the current display value is a Net weight Value.

The fourth LED from left to right is the Print Status Indicator and will be ON for a moment
when the scale sends out the print data from any channel on the communication port.


The fifth LED from left to right is normally for the “kg” unit indication, however this may also
be used as the indicator of either “g” or “oz” Units.

The sixth LED from left to right is normally for the “lb” unit indication, however this may also
be used as the indicator of either “oz” or “g” Units.


The last LED from left to right is the Low Battery Indicator for battery operated applications.

In the setup mode, the blinking of this LED is an indication to enter the numeric value.

Low Battery Indicator

Pound Unit Indicator

Kilogram Unit Indicator

Print Status Indicator

Net Mode Indicator

Zero Status Indicator

Stable Status Indicator