1 weighing, 2 hold/release function, 3 preset tare – Rice Lake Floor Level Digital Physcian Scale (150-10-7) - RL150-10-7 Operation Instructions User Manual

Page 10: 4 toggle tare

Advertising
background image

ENTER

6

Rice Lake Digital Floor Level Scale Operation Instructions

The keys on the front panel display are very sensitive so only a gentle pushing motion is required.

The scales have the capability of performing different operations beyond just calculating weight. The various

operating instructions are described below.

4.1

Weighing

Use the following steps to weigh a person.

1. Press the

On/Off

key to turn on the scale and

0.0

will appear on the display along with

ZERO

on the upper

display.

2. When the person step on the scale the display shows the person’s weight. The

LOCK

annunciator is on in

the upper display and beeps to indicate the end of the weighing process.

3. To change the display from kg to lb and vice-versa, press the

LB/KG

key.

4. To turn off the scale, press and hold the

On/Off

key until

OFF

appears on the display.

4.2

Hold/Release Function

Use the following steps to use the Hold/Release function.

1. When the person is on the scale, press the

Hold/Release

key.

2. When the person steps off the scale, the weight and the

HOLD & LOCK

annunciator will remain on the

display.

3. At this stage the

Zero

key will not work. The only way to return to zero from here is to press the

Hold/

Release

key one more time.

Note

Pressing the Hold key prior to a person getting on the scale will also work.

4.3

Preset Tare

Use the following steps to use the Preset Tare.

1. When the weight is set to

0.0

, place the extra load on the scale. Press the

TARE

key until the display

returns to

0.0

and

NET

appears on the display.

2. Remove the extra load from the scale. The weight will appear with a negative symbol to the left of it.
3. Ask the patient to step on the scale with the extra weight. The display shows the patient’s weight. The

NET

annunciator is still on. The weight of the extra load remains stored in memory.

4. To cancel the tare weight, press and hold the

TARE

key until

NET

disappears from the display and the

display turns back to

0.0

and

GROSS

appears. Tare weight is also cancelled when the scale is turned off.

4.4

Toggle Tare

Use the following steps to use the Toggle Tare function.

1. When the weight is set to

0.0

, press the

TARE

key.

2. The default tare value is displayed (default is programmed to be 33.0 lb/15.0 kg), while the zero is

flashing.

3. Use the

Up/Down

arrow keys to adjust the value.

4. Press

ENTER

to start the tare function and the

NET

annunciator will be turned on instead of the

GROSS

annunciator.

ENTER

Used to accept height in BMI mode.
Accepts the value of the parameter last entered and moves to the next stage.
A long press of the ENTER key during the scale’s start up process will enter
the ID display (pre-parameter mode).

Up/Down Arrows

Used to adjust height input (0.5 in/0.5 cm) while in BMI mode.
Adjusts the value of the flashing digit/number.

Note

Key

Name

Function

Table 4-1. Rice Lake Digital Floor Level Scale Key Functions

Advertising