IQ plus 350 Analog Output Option

Enclosure Reassembly

Once cabling is complete, position the backplate over
the enclosure and reinstall the backplate screws. Use
the torque pattern shown in Figure 8 to prevent
distorting the backplate gasket. Torque screws to 15
in-lb (1.7 N-m).

Figure 8. IQ plus 350 Enclosure Backplate

Analog Output Calibration

The following calibration procedure requires a
multimeter to measure voltage or current output from
the analog output module. No test weights are
required for calibration.

NOTE:

The analog output must be calibrated

after

the

indicator itself has been configured and calibrated.

Figure 9. Analog Output Menu

1. Enter setup mode and go to the ALGOUT

menu (see Figure 9).

Set OFFSET to 0% for 0–10 V output,
20% for 4–20 mA output

Set MIN to lowest weight value to be
tracked by the analog output

Set MAX to highest weight value to be
tracked by the analog output

To enter MIN and MAX values, use the and

keys to select the digit; use and to

increment or decrement the value.

2. Connect multimeter to analog output:

For voltage output, connect voltmeter
leads to pins 3 and 4

For current output, connect ammeter
leads to pins 1 and 2

3. Adjust zero calibration: Scroll to the

TWZERO parameter. Check voltage or
current reading on multimeter. Press and hold

or to adjust the zero value up or down.

4. Adjust span calibration: Scroll to the

TWSPAN parameter. Check voltage or
current reading on multimeter. Press and hold

or to adjust the span value up or down.

5. Final zero calibration: Return to the

TWZERO parameter and verify that the zero
calibration has not drifted. Press and hold
or to re-adjust the zero value as required.

6. Return to normal mode. Analog output

function can be verified using test weights.

S e t u p s w i t c h a c c e s s s c r e w

Fillister head screws

10

9

8

7

4

3

1

2

5

6

To r q u e b a c k p l a t e s c r e w s t o 1 5 i n - l b ( 1 . 7 N - m )

To r q u e p a t t e r n

XXXXXXX

XXXXXXX

VERS

ALGOUT

DIG IN

XXXXXXX

PROGRM

PFORMT

SERIAL

CALIBR

XXXXXXX

CONFIG

FORMAT

SOURCE

GROSS

0%

20%

OFFSET

ERRACT

FULLSC

HOLD

000000

number

MIN

10000

number

MAX

TWZERO

NET

TWSPAN

ZEROSC

Advertising
This manual is related to the following products: