3 front panel configuration, Front panel configuration, Using the menus is described in section 3.1.3 – Rice Lake Farm Bars - IQ plus 390-DC User Manual

Page 15: Setup mode key functions

Advertising
background image

Configuration

11

3.1.3

Front Panel Configuration

The IQ plus 390-DC indicator can be configured using a series of menus accessed through the indicator front
panel when the indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.

Figure 3-2. Front Panel Key Functions in Setup Mode

Four front panel keys are used as directional keys to navigate through the menus in setup mode (see Figure 3-2).
The

UNITS

( ) and

PRINT

( ) keys scroll left and right (horizontally) on the same menu level;

ZERO

( ) and

GROSS/NET

( ) move up and down (vertically) to different menu levels. The

TARE

key ( ) serves as an Enter

key for selecting parameter values within the menus. A label over each of these keys identifies the direction
provided by the key when navigating through the setup menus.

Figure 3-3. Setup Mode Menu Navigation

Menu

Menu Function

CONFIG

Configuration

Configure grads, zero tracking, zero range, motion band, overload, tare function, and digital
filtering parameters.

FORMAT

Format

Set format of primary and secondary units, display rate.

CALIBR

Calibration

Calibrate indicator. See Section 4.0 on page 22 for calibration procedures.

SERIAL

Serial

Configure serial port.

PROGRM

Program

Set power-up and standby modes, counting scale functions, regulatory mode, unit ID and
consecutive number values.

P FORMT

Print Format

Set print format used for gross, net, and counting scale tickets. See Section 7.0 on page 29
for more information.

VERSION

Version

Display installed software version number.

Table 3-1. IQ plus 390-DC Menu Summary

T

ZERO

GROSS

NET

TARE

UNITS

PRINT

T

B/N

Units

POWER

ENTER

SAMPLE

MODE

PRINT

I / O

Move LEFT /

Previous

Move RIGHT /

Next

Move UP /

Increment Value

Move DOWN /

Decrement Value

ENTER Value

SETUP MODE KEY FUNCTIONS

1

st

Level

Parameter

Default value

2

nd

Level

Parameter

Value

Value

Value

1

st

Level

Parameter

2

nd

Level

Parameter

When moving through values below the first menu level, press

to return to the level

above. Press

or

to move to the next parameter on the level above.