Rice Lake MSI6260cs Digital Crane Scale Operator Manual User Manual

Page 17

Advertising
background image

MSI-6260CS Crane Scale™

User Guide Page 17

MEASUREMENT SYSTEMS INTERNATIONAL

Rev 1 4/14/06 for SW Ver 5-xx

GENERAL SPECIFICATIONS

Calibration Parameters (Programmed via Terminal Access Mode)

CAL – Zero then Span, up to 10 point calibration (counting 0)

• AZM – OFF, ON (.5d), 1d to 255d Programmable
• Motion Detect – OFF, ON (.5d), 1d to 255d (programmable in 1d steps)
• Software Filter – None, LOW, HIGH
• Zero – 100% of capacity, limited by Legal-for-trade settings.
• Units – lb, kg, Ton, Ton (metric), oz, g, daN, or user defined using the math channels through remote indi-

cators (3750CS or 9750).

• Standard Crane Scale Capacities – 500 lb / 250 kg, 2000 lb / 1000 kg, 5000 lb / 2500 kg, 10000 lb /

5000 kg, 20000 lb / 10000 kg, 30000 lb / 15000 kg, 50000 lb / 25000 kg, 70000 lb / 35000kg, 100000 lb /

50000kg. Larger capacities available on request. MSI can provide load cells to 500 tons. Any scale can be

calibrated to a smaller capacity. e.g. a 2000 lb scale could be calibrated to overload at 1800 lb.

• “d” Scale divisions – Any resolution from 10,000 divisions or less. Standard 6260CS resolution is 2000d

to 5000d. Having more resolution than needed can cause settling delay.

Power Consumption
• Battery Life – 30-40 Hrs with new battery.
Approvals (pending)

NTEP, OIML, Factory Mutual, NEMA, FCC

Temperature

Operating

NTEP/OIML

-40°C to 85°C (-40° to 185° F)

-10°C to 40°C (14° to 104° F)

RFI/EMI Shielding

Exceeds NIST HB44 and European Standards.

Real Time Clock
• Supports date/time stamping in US or European time and date. Backed up by a replaceable Lithium Bat-

tery (Typical life >5 years). Clock data available via RF interfaces (3750CS, 9750, 9020).

Data I/O
• Any scale data is available via RF Modem or through the 3750CS or 9750 Indicators.

Totalization and Statistics
• Push button or Automatic. Total weight up to 999,999,999. Weighments counter up to 65,535. Totals are

stored with each ID register. Min, Max, Average, Standard Deviation, and Coefficient of Variance com-

puted and stored for each ID.

Internal Set Points
• 3 Contacts internal (SS Relays). Programmable for form A or form B (normally open or normally closed).

Relays rated for 60V @ 350mA. 2.5Ω maximum contact resistance. Accessible by special order.

Advertising