BATTERY REMOVAL & REPLACEMENT

1) Turn the 6260CS Off.
2) With one hand, hold the battery access cover.
3) Release the two latches holding the battery access cover.
4) Carefully lower the cover and when possible, hold the battery in place. The battery might be loose and

subject to falling.

5) Remove the battery by pulling straight back.
6) Install a fully charged battery by plugging it in to the exposed battery jacks. The 6260CS may or may not

turn on once the new battery is installed.

7) Reseat the access panel.
8) Reset the latches. Make sure the latches are completely latched and the plate is firmly in place.

The charger is a universal input type and is rated for 100-240VAC, 50-60Hz. AC power cords suitable for any

world location are available from MSI.

Charge Indicator Light

Amber = Charging

Green = Float