120 degrees

maximum

Load

Sling Angle

Factor

Load

L

H

• Use bottom shackle with hook for two sling

leg loading.

• Never exceed 120° included angle.

• Shackle load rating is based on vertical

axis line loading Shackle capacity
decreases as sling angle increases from
vertical axis.

Horizontal Sling

Angle(A) Degree

Sling Angle

Factor = L/H

90

1.000

60

0.866

50

0.766

45

0.707

30

0.500

Load on each leg of sling = verticle
share of load x load angle factor

6

MSI Crane Scale

Safety Manual

Figure 3-3. Loading the Scale Hook with Multiple Sling Legs