Available DIP switch settings (Parallel Interface)

The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switch 8.

A reset can be performed with pin 31 on the interface by setting DIP switch 1 to
ON (the factory default setting).
In addition, when a reset can be performed with pin 31, setting DIP switch 2 to
OFF sets up the unit to perform a reset when pin 31 and pin 36 are “LOW”.

*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.

Switch

Parameter

ON

OFF

1

Pin 31 / Pin 36 Reset Signal

See table below.

2

3

Not used

(Always ON)

4

5

6

7

Command Emulation

See table below.

8

Reset Signal

Switch 1

Switch 2

Pin 31 is enabled.

ON

ON

Pin 31/Pin 36 are enabled.

ON

OFF

Disabled

OFF

ON

Disabled

OFF

OFF

Command Emulation

Switch 7

Switch 8

Star mode

ON

ON

ESC/POS (TM-295)

ON

OFF

ESC/POS (TM-290)

OFF

OFF

Not used (*1)

OFF

ON