Available dip switch settings (parallel interface), 128 appendix – Rice Lake Star SP298 Users Manual User Manual
Page 131
128
APPENDIX
Available DIP switch settings (Parallel Interface)
The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switch 8.
A reset can be performed with pin 31 on the interface by setting DIP switch 1 to
ON (the factory default setting).
In addition, when a reset can be performed with pin 31, setting DIP switch 2 to
OFF sets up the unit to perform a reset when pin 31 and pin 36 are “LOW”.
*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.
Switch
Parameter
ON
OFF
1
Pin 31 / Pin 36 Reset Signal
See table below.
2
3
Not used
(Always ON)
4
5
6
7
Command Emulation
See table below.
8
Reset Signal
Switch 1
Switch 2
Pin 31 is enabled.
ON
ON
Pin 31/Pin 36 are enabled.
ON
OFF
Disabled
OFF
ON
Disabled
OFF
OFF
Command Emulation
Switch 7
Switch 8
Star mode
ON
ON
ESC/POS (TM-295)
ON
OFF
ESC/POS (TM-290)
OFF
OFF
Not used (*1)
OFF
ON