5 remote display/indicator programs, Remote display / indicator programs, Program # indicator and operating mode – Rice Lake Remote Displays/Scoreboards - 234HE User Manual

Page 7

Advertising
background image

6

5.

Remote Display / Indicator Programs

Program #

Indicator and Operating Mode

F1_5-1D

UMC1000, UMC2000, IQ600, IQ700 — Continuous

F1_5-1D

Thurman EDS4 - EPROM in indicator is Continuous Condec format

F1_5-2B

UMC 1000, 2000 — Demand

F1_5-3B

Toledo 8140, 8142, 8530, 8132

1

, 9481 — Continuous

F1_5-3B

Fairbanks 9201RS-232 (Use COM port 1 only)

F1_5-4D

IQplus 800/810, IQplus 310 Continuous (End of line set to CR/LF)

F1_5-5A

StreeterAmet 9000 — Continuous

F1_5-6A

Cardinal 738 — Continuous

F1_5-7A

Western DF1000 — Continuous

F1_5-8A

Pennsylvania 5600 — Continuous

F1_5-9A

Flexweigh DWM IV — Continuous

F1_5-10A

IDS print w/BCD to 20 mA conversion — Continuous

F1_5-11A

AD 4321 — Continuous (Format 1, display will not show negative sign)

F1_5-12A

IQ700 Truck ID for KBB 8-1, Ver. EF EPROM

F1_5-13A

Analogic 5316 — Continuous, HB 44 (EPROM 13.0 shows gross only)

F1_5-14A

Electroscale 533 — Continuous

F1_5-15A

IQ700, IQplus 310 Demand (Net or Gross) with Time and Date

F1_5-16A

WI-110, WI-120, WI-130 — Continuous

2

F1_5-17A

Toledo 8142 with BCD Converter

F1_5-18A

Doran 7000 — Continuous

F1_5-19A

Fairbanks 90-164-1, 90-166-1, 9201 (out Com 2) — Continuous (20 mA passive only)

F1_5-1C

UMC 1000, UMC 2000, IQ600, IQ700 — Continuous

F1_5-21A

Electroscale 551 — Continuous

F1_5-22A

Analogic 5316, EPROM Revision 13.0.9 — Continuous

F1_5-23A

General Freedom I and II — Continuous

F1_5-24A

ACCU-WEIGH SEP-12K, Format 8 — Continuous

F1_5-25A

Kubota KA-10 — Continuous

F1_5-26A

Flexweigh DWMIV Continuous w/Post & Preamble (02H, 03H)

F1_5-27A

MSI TRANS-WEIGH — Continuous

F1_5-28A

OHAUS 1150 — Continuous

F1_5-29A

Hardy HI 2151 WC — Continuous

F1_5-30A

Pennsylvania 3100 — Continuous

F1_5-31A

IQplus 800/810 — Demand (Standard default format)

F1_5-32A

IQplus 310 — Demand (Net Weight Only)

F1_5-33A

IQplus 310 — Demand (Gross Weight Only)

F1_5-34A

Fairbanks 90-163-1 — Continuous

F1_5-36A

IQ700, IQplus 310, — Demand (Net or Gross) with Time and Date

F1_5-37A

Tyrel TC-10 / Howe-Richardson HR500k Continuous

F1_5-38A

Tara TR-1 Continuous, 1200 baud, fixed 8 bits, no parity, 2 stop bits

F1_5-39A

Allegany Mega 8—Continuous

3

F1_5-40A

A-N-D FG Bench Scale

F1_5-41A

Cardinal 748 — Continuous

F1_5-42A

3-weight 810 — Continuous

4

Notes:
1

The Toledo 8132 meter will not work with the 234HE without special programming to operate the 234HE at 4800 baud.

2

The WI130 indicator must be programmed to stream out in the standard Weightronix format to use the WI110/WI120 flip digit driver.

3

The Allegany Mega 8 sends out eight weight display digits. The EL234HE Remote Display shows the least significant six digits.

4

This special format contains three weight strings within one serial string. Dip switches 7 and 8 in switchbank 2 control which of the three
strings are displayed as follows:

2-7

2-8

String Displayed

off

off

1st

off

on

2nd

on

off

3rd

Advertising