Rice Lake Mobile Group Animal Scale - MAS-M - Particulate Filter User Manual

Particulate filter installation instructions, Mas-m animal scale

Advertising
background image

March 2014

161509

MAS-M Animal Scale

Particulate Filter Installation Instructions

PN 161442

The particulate filter removes water and debris from the compressed air system on the MAS-M animal scale.

Tools Needed

9/16" wrench

12" adjustable wrench

Kit Contents Include:

Particulate filter

Thread seal tape

Super glue adhesive

Black tubing

Brass fitting male, elbow 1/4 NPT

Brass fitting elbow 90

°

extruded street 1/4 NPT

The following instructions describe in step-by-step detail how to install the particulate filter:

1. Open the relief valve on the outside of the

battery box.

2. Open the two latches on the outside of the

battery box.

3. Remove front cover and set aside.

Battery Removal

4. Remove battery connection covers.

5. Disconnect the negative lead (black) using a

9/16" wrench.

CAUTION

While removing battery, be careful not
to allow loose leads to touch as it may
cause accidental sparking.

6. Disconnect the positive lead (red) using the

same 9/16" wrench.

7.

Unhook the blue strap that holds the battery in place.

8. Cover the positive side of the battery with the

red rubber cap to protect the operator from
accidental sparking while removing the
battery.

9. Pull battery out of battery box and set aside.

Dismantle Existing Air Line

10. Remove air line by pushing up on the fitting

a n d p u l l i n g d o w n o n t h e a i r l i n e
simultaneously.

Advertising