Appendix e: periheral unit drive circuit, Peripheral drive connector, Viewed from connector surface – Rice Lake Star TSP-700 - User Manual User Manual
Page 97
– 94 –
APPENDIX
Notes 1. Pin 1 must be shield drain wire connected to peripheral device
frame ground.
2. It is not possible to drive two drives simultaneously.
3. The peripheral drive duty must satisfy the following:
ON time / (ON time + OFF time)
≤
0.2
4. The resistance of the peripheral drive solenoid must be 24
Ω
or
higher.
If it is lower than 24
Ω
, over-current may flow into the solenoid,
causing the solenoid to burn.
Modular plug
Peripheral Drive Connector
Pin No.
Signal
Function
I/O
name
direction
1
FG
Frame ground
—
2
DRD1
Drive signal 1
OUT
3
+24V
Drive power
OUT
4
+24V
Drive power
OUT
5
DRD2
Drive signal 2
OUT
6
DRSNS
Sense signal
IN
6
1
<Viewed from Connector Surface>
Appendix E: Periheral Unit Drive Circuit
Peripheral unit drive circuit connector only connects to peripheral units such as
cash drawers, etc.
Do not connect it to a telephone.
Use cables which meet the following specifications.
16
Modular plug: MOLEX 90075-0007,
AMP641337, or BURNDY B-66-4
Wire lead
Separated Ground wire
connected to shield
(Europe only).
Shield