TradeRoute Checklist for Installation

9. Hydraulics

Verify that there are available onboard hydraulics that can meet the scale system performance specifications:

Maximum pressure of 3000 psi and 5 GPM flow rate (although a lower flow rate will only result in a
slower lifting and lowering speed of the scale).

If no onboard hydraulics exist, the installer must provide for this.

10.Indicator/Printer Mounting

Determine in advance how and where the digital indicator and printer, whether the in cab or outdoor version, will
be mounted, and where the hydraulic lifting and lowering controls will also be mounted for the convenience of the
operator.

In Cab Indicator

Outdoor Enclosure

Figure 6. Indicator/Printer Location

11. Test Weights for Calibration

Establish how the scale will receive test weights for calibration. Discuss this with the end user and scale dealer, if
necessary.

Platform Loading

Hanging Test Weights

Figure 7. Test Weight Loading