Electrical safety, Safety devices, Risk of electrocution – Snow Joe SPX1000-RM Pressure Joe 1450 PSI 1.45 GPM 11.5-Amp Electric Pressure Washer User Manual

Page 2

Advertising
background image

m

WARNING!

During cleaning, maintenance or when

replacing parts, the machine must be disconnected from its
power source by removing the plug from the socket outlet.

m

WARNING!

High pressure hoses, fittings, and couplings

are important for the safe operation of the appliance. Use
only hoses, fittings, and couplings recommended by the
manufacturer.

Check for damaged parts – Do not use the appliance if the
supply cord or other important parts of the appliance are
damaged (e.g. safety devices, high pressure hoses, trigger
gun).

m

WARNING!

If an extension cord is used, the plug and

socket must be of watertight construction.

m

WARNING!

Inadequate extension cords can be

dangerous.

• This high pressure washer must not be used at

temperatures below 32ºF (0°C).

m

WARNING!

Power cords on drums should always be

completely unwound to prevent the cord from overheating.

• Power cord connections should be kept dry and off the

ground.

• Comply with the below requirements for length and cord

specs (Table 1):

• If the power cord is damaged, it must be replaced by the

manufacturer or his service agent or similarly qualified
person in order to avoid a hazard.

• Keep the machine on a stable, flat surface during operation,

handling, transportation, and storage. Sudden overturn of
the machine can cause bodily injury.

• In the event of an accident or breakdown, switch off the

machine immediately. (If contact with detergent occurs,
rinse with an abundance of clean water.)

Electrical Safety

ATTENTION:

If there are problems with the electrical

MAINS, short voltage drops may appear when starting the
equipment. This can, in turn, influence other equipment (e.g.
cause a lamp to blink). If the MAINS-IMPEDANCE Zmax <

0.335 OHM, such disturbances are not expected. (In case
of assistance, contact your local supply authority for further
information.)

m

WARNING!

Electrical Shock Hazard

Before starting up your machine, please check it carefully for
any defects. If you find any, do not start up your machine and
contact your distributor.

The following should be observed when connecting the high
pressure washer to the electric installation:

• The electric supply connection should be performed by a

qualified person.

• The electric supply to this appliance should include either

a residual current device that will interrupt the supply if the
leakage current to the earth exceeds 30 mA for 30 ms or a
device that will interrupt the earth circuit (GFCI).

IMPORTANT:

Only use water without any impurities.

If there is a risk of running sand into the inlet water (i.e. from
your own well), an additional filter should be installed.

Safety devices

The unloader valve can reduce pressure if it exceeds preset
values. The spray gun features a locking device. When the
lock is activated, the spray gun cannot be operated.

Thermal sensor – A thermal sensor protects the motor
against overloading. The machine will restart after a few
minutes when the thermal sensor has cooled.

Double insulation – In a double-insulated product, two
systems of insulation are provided instead of grounding.
No grounding means are provided on a double-insulated
product, nor should a means for grounding be added to
the product. Servicing a double-insulated product requires
extreme care and knowledge of the system, and should be
performed only by a qualified service person. Replacement
parts for a double-insulated product must be identical to the
parts they replace. A double-insulated product is marked
with the words “DOUBLE INSULATION” or “DOUBLE
INSULATED”. The symbol “ ” may also be marked on the
product.

Ground Fault Circuit Interrupter (GFCI) – This pressure
washer is provided with a ground-fault circuit-interrupter
(GFCI) built into the plug of the power-supply cord. This
device provides additional protection from the risk of
electric shock. Should replacement of the plug or cord
become necessary, use only identical replacement parts
that include GFCI protection.

Risk of electrocution

• Inspect cord before using.
• Do not use if cord is damaged.
• Keep all connections dry and off the ground.

Table 1

25

18

18

16

50

16

16

16

100

16

14

150

14

12

Volts
120V

0 – 6

6 – 10

10 – 12

Total length of cord in feet

AWG

Not Recommended

Ampere Rating

More than

Not more than

2