Table 2. Explanation of Configuration Settings

Parameter Type

Description

Default
Value

Version

Read Only

The firmware version of the CC640 operating system

N/A

PakBus Port

Read/Write

Options: NONE, CS I/O, RS-485, RS-232

NONE

Only select a PakBus Port if communications are being used to
transfer images via PakBus.

PakBus Address

Read/Write

Options: 1 – 4094

55


A PakBus Address should be assigned to the camera for
PakBus Communications.

PakBus Destination

Read/Write

Options: 1 – 4094

1

Address


This is the PakBus address of the destination device where the
image files will be transmitted. The device is normally a
Campbell Scientific datalogger.

Extra
Communications
Delay

Read/Write

Options: 0 – 10 Seconds

1


Additional Delays can be added for PakBus networks with
long propagation delays.

RS-485 BAUD rate

Read/Write Options: 230400, 115200, 76800, 57600, 38400, 28800,

19200, 9600, 1200

115,200

RS-232 BAUD rate

Read/Write Options: 230400, 115200, 76800, 57600, 38400, 28800,

19200, 9600, 1200

115,200

CS I/O SDC

Read/Write

Options: 7 or 8

8

ADDRESS


If other CSDC devices are connected to the same CS I/O port,
each device must have its own address.

Read/Write

Compression Level

Options: Very High, High, Medium, Low, None

High


This option selects the amount of compression to be applied to
the JPG files. Higher compression levels result in smaller files
but the images will lose subtle details. Selecting none will
produce a large sized (480Kb) Lossless image.

Start Minute

Read/Write Options:

0-1339

0


If the camera is in a Self-Timed Mode, this parameter allows a
start time from Midnight to be selected.

Stop Minute

Read/Write Options:

0-1440

1440


If the camera is in a Self-Timed Mode, this parameter allows a
stop time from Midnight to be selected.

Self-Timed Interval

Read/Write Options:

0-1440

0


If this parameter is non–zero then the camera will
automatically wake itself up and acquire images based on the
interval entered.

Motorized Enclosure

Read/Write

Options: Disable, Enable

Disable


Select enable if the ENC-CC motorized covered enclosure is
used. It is important to select disable if the motorized
enclosure is not used. Selecting enable when a motorized
enclosure is not present will slow down the operation of the
camera.

Firmware Checksum

Read Only

This is the checksum calculated from the firmware present on
the camera.

N/A

16