- 5 -

NOTE:
To prepare rough-in, leave minimum 4” clearances for electrical wiring and
refrigeration piping.

The specifications and dimensions are listed as follows:

Model No

Evap Unit

L”xD”xH”

Cond Unit

L”xD”xH”

Btu/h

CFM

Cellar Size

(cu ft)

Refrigerant

Electrical

Evap Unit/

Cond Unit

Weight (lb)

Evap Unit/

Cond Unit

WM-

2500SSR

WM-25SFCR

32x11.125

x11.375

WM-250SCU

18x14x12

2500

220

250 R134a

115V-60HZ-0.77A

115V-60HZ-5.7A

25/40

WM-

4500SSR

WM-45SFCR

38x11.125

x14.375

WM-450SCU

18x14x12

4500

335

1000 R134a

115V-60HZ-0.77A

115V-60HZ-6.9A

35/60

WM-

6500SSR

WM-65SFCR

38x11.125

x14.375

WM-650SCU

24x18x18

6500

420

1500 R134a

115V-60HZ-1.9A

115V-60HZ-12A

45/60



Also see Fig. 3, 4 & 5 for further info.