PRODUCT SPECIFICATIONS

MODEL

RHD/H/I -6400P

400WATT ATX HIGH PERFORMANCE REDUNDANT

POWER SUPPLY (ACTIVE POWER FACTOR CORRECTION)


A

INPUT CHARACTERISTICS

1

VOLTAGE

FULL RANGE, SINGLE PHASE, 90

264VAC

2

FREQUENCY

47

63HZ

3

INPUT CURRENT

2.5A

RMS

FOR 230VAC; 7A

RMS

FOR 115VAC

4

INRUSH CURRENT

65A MAX. FOR 115 VAC PER MODULE

125A MAX. FOR 230 VAC PER MODULE


B

OUTPUT CHARACTERISTICS

OUTPUT

OUTPUT CURRENT

OUTPUT VOLTAGE REGULATION OUTPUT RIPPLE

& NOISE (p-p)

VOLTAGE

MIN. MAX.

RANGE MIN NOM MAX MAX.

+5V 5.0A

35

A 5%

+4.75 +5.00 +5.25 60mV

-5V 0A

0.8A 5%

-4.75 -5.00 -5.25 100mV

+12V 2.5A

20A

5%

+11.40 +12.00 +12.60 100mV

-12V 0A 1A

5%

-11.4 -12.00 -12.60 100mV

+3.3V 1.0A 28A

5%

+3.13 +3.33 +3.47 60mV

+5VSB 0.1A 2A

5%

+4.75 +5.00 +5.25 60mV

TOTAL POWER: 400W (MAX.)

NOISE BANDWIDTH : DC TO 20MHZ.


C

SPECIFICATION

TEMPERATURE RANGE

OPERATING 0

40

STORAGE -20

80

HOLD UP TIME

16ms

MIN.

DIELECTRIC WITHSTAND

INPUT/OUTPUT 1500 VAC FOR 1 minute

INPUT TO FRAME GROUND 1500 VAC FOR 1 minute

HUMIDITY

10

90%RH

EFFICIENCY

67% TYPICAL AT 115V

AT FULL LOAD

POWER GOOD SIGNAL

ON DELAY 100ms TO 500ms

OFF DELAY 1ms

OVER LOAD PROTECTION

110

150% MAX

OVER CURRENT PROTECTION :+5V

44A

60A; +3.3V

33A

45A; +12V

29.1A

40.5A

OVER VOLTAGE PROTECTION

+5V

5.7V

6.5V; +3.3V

3.9V

4.3V;

+12V

13.6V

15V

EMI:

FCC CLASS B , CISPR 22 CLASS B

SAFETY

EACH POWER UNIT SHALL BE FULLTY COMPLYING
WITH THE UL / CSA / TÜV APPROVAL

ALARM METHOD:

1) AUDIO ALARM 2) FAULT LED INDICATOR

3) POWER DEFECTIVE SIGNA

HOT-SWAPPABLE & HOT-PLUGABLE CAPABILITY
MEET

IEC-1000-3-2 CLASS D (ACTIVE PFC)

DIMENSION

213mm*183mm*154mm

(D*W*H)

12