Symbology – Chicago Electric 7" Electronic Polisher 66615 User Manual

Page 9

Advertising
background image

Page 9

For technical questions, please call 1-800-444-3353.

SKU 66615

When using more than one extension

4.

cord to make up the total length, make

sure each cord contains at least the

minimum wire size required.

(See Table a.)
If you are using one extension cord for

5.

more than one tool, add the nameplate

amperes and use the sum to determine

the required minimum cord size.

(See Table a.)
If you are using an extension cord

6.

outdoors, make sure it is marked with the

suffix “W-A” (“W” in Canada) to indicate it

is acceptable for outdoor use.
Make sure the extension cord is properly

7.

wired and in good electrical condition.

Always replace a damaged extension

cord or have it repaired by a qualified

electrician before using it.
Protect the extension cords from sharp

8.

objects, excessive heat, and damp or

wet areas.

RECOMMENdEd MINIMuM WIRE gaugE

FOR EXTENSION CORdS*

(120/240 VOLT)

NaMEPLaTE

aMPERES

(at full load)

EXTENSION CORd

LENgTH

25’ 50’ 75’ 100’ 150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TaBLE a

* Based on limiting the line

voltage drop to five volts at 150%

of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

a

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

REV 10b

Advertising