B&C Technologies DP-250 Industrial User Manual

Page 32

Advertising
background image

INSTALLATION PROCEDURES

3-18

Figure.3-11 Steam Damper System.

3. Steam Damper Air System Connections

The dryer is manufactured with a pneumatic (piston) damper system which requires an

external supply of compressed air. The air connection is made to the steam damper solenoid valve
which is located at the rear inner top area of the dryer just above the electric service relay box

Air Requirements

Table 3-5 Table For Air Pressure.

Compressed Air Supply

Air Pressure

Normal 80

psi

Minimum Supply

70 psi

Maximum Supply

90 psi

Air Connection

Air connection to system 8 mm.

No air regulation or filtration is provided with the dryer. External regulation/ filtration of 80

psi must be provided. It is suggested that a regulator / filter gauge arrangement be added to the
compressed air line just before the dryer connection. This is necessary to insure that correct and
clean air pressure is achieved.

4. Steam Damper System Operations

The dryer steam damper, as. Allows the coil to stay constantly charged eliminating repeated

expansion and contraction. When the damper is opened, the air immediately passes through the
already hot coil, providing instant heat to start the drying process. When the damper is closed,
ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down.