B&C Technologies DP-250 Industrial User Manual

Page 33

Advertising
background image

INSTALLATION PROCEDURES

3-19

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).
Diagram 2 shows the damper in the cool down (closed) mode, pulling ambient air directly into the
basket (tumbler) without passing through the coils.

NOTE: With the dryer off or with no air supply, the damper is in the cool down mode as shown in
Diagram 2.

Figure.3-12 Steam Damper System.

5. Steam Damper Air Piston (Flow Control) Operation Adjustment

Although the damper operation was tested and adjusted prior to shipping at 80 Psi, steam

damper operation must be checked before the dryer is put into operation. damper air adjustment is
necessary, locate flow control valve and make necessary adjustments as noted below.

Figure.3-13 Steam Damper Operation Adjustment

Air connector

Wire size 8 mm.

Flow control valve

Solenoid valve

Damper air cylinder

Air flow

Air flow

Diagram 2

Cool Down Mode

Diagram 1

Heating Mode

Air flow