4. Increase the volume and verify that the amplifier reproduces the audio at full

frequencies without distortion.

If you hear distortion check the connections and verify that the gain control is set
correctly. Another cause of distortion could be underpowered or damaged
speakers. Refer to Troubleshooting.

6. TROUBLESHOOTING

Indicator lights

The APX2181, APX4361, DPX1851 and DPX11551 have lights that indicate
amplifier status.

Blue top

Red end-

Blue end-

LED

panel light

panel light

Meaning

On

Off

Off

Amplifier running normally

On

Alternating between

In thermal protection mode

red and blue

Slow blink

Slow out-of-sync

Off

Over voltage;

blink

reduce the input voltage

Quick blink Quick in-sync

Off

Short circuit protection

blink

3 blinks,

3 blinks,

Off

Repeated shorts detected;

then pause

then pause

remove the short circuit, wait
5 minutes for error condition
to clear; or clear condition by
removing the main power, for
example, by pulling the fuse.

No Audio

• L ow or no remote turn-on voltage: check remote connections at the amplifier

and source unit.

• Blown amplifier fuse: replace with a new fast-blow fuse (same rating).

• Power wires not connected: check battery and ground wiring at the amplifier

and check the battery connections.

• Speaker leads shorted: check speaker continuity to ground; it should not show a

common ground.

• Speakers not connected or are bl own: check speaker connections at the

amplifier and measure at speakers. Measure coil impedance at amplifier with
speaker wires disconnected.