Martin Engineering M3286-8/01

7

MOTOMAGNETIC

®

Electric Vibrators

WARNING

!

If vibrator is mounted more than 6 in. (152 mm) above
ground, install cable securing vibrator to structure. Without
cable, vibrator could fall and cause injury.

8. Secure vibrator to structure by installing MARTIN

®

BBAC Cable Kit,

P/N 32271, or equivalent as follows (cable is included with Mount Kit for
Electric Vibrators, P/N 32401-XX):

a. Weld D-ring (A, Figure 4) onto structure wall (B) above vibrator.

Figure 4. Installing Restraining Cable

b. Loop 1/4-in. (6 mm) wire cable (C) through vibrator lifting eye (D)

and D-ring on structure wall.

c. If using a MARTIN

®

W-Beam Mount, also loop cable through D-ring

on W-Beam (E) as shown. Take up slack so cable is taut.

d. Apply thread-sealing compound to nuts on cable clamps (F). Install six

cable clamps (two on each end and two on loop around D-ring on

W-beam) to secure cable to vibrator eye and D-rings. Torque nuts on
cable clamps according to drawing B-32401-XX supplied with Mount
Kit for Electric Vibrators.

e. Trim loose ends of wire cable.

A

B

D

C

E

F

A.
B.
C.
D.
E.
F.

D-ring
Structure wall
Wire cable
Vibrator lifting eye
D-ring on W-Beam
Cable clamp (6)