Initial start up/ checking line current, Warning, Caution – Metalfab Martin Motomagnetic Electric Vibrator User Manual

Page 21: After installation

Advertising
background image

Martin Engineering M3286-8/01

17

MOTOMAGNETIC

®

Electric Vibrators

Figure 11. Setting Sets of Eccentric Weights to Mirror Images

Initial start up/
checking line
current

1. Close power supply disconnect switch and allow motor(s) to operate for

10 to 20 minutes.

2. If vibrator makes unusual or excessive noise, make sure mounting bolts

are tight and mount welds are not damaged.

WARNING

!

Vibrator may produce loud noise during operation when
mounted on structure. See OSHA 1910.95 for guidelines. If
required, wear ear protection to avoid impairment or loss of
hearing.

3. Check decibel level of vibrator noise during operation. See OSHA

1910.95 to determine whether noise exceeds safe limits. If required, wear
ear protection to avoid impairment or loss of hearing.

CAUTION

!

Do not allow motor current to exceed nameplate rating. If
vibrator is operated continuously with line current above
nameplate rating, vibrator can be damaged.

4. After a few hours of operation, check each line current. If reading is

higher than nameplate rating, reduce eccentric weight setting, stiffen
vibrator mount, or move vibrator to more rigid location. After making
adjustments, check line current again to ensure line current does not
exceed nameplate rating.

5. After first 8 hours of use and periodically thereafter, check mounting bolts

and tighten if necessary.

After Installation

Advertising