Dip switch selection, Optional connections (cont’d) – Chamberlain LM21XP User Manual

Page 9

Advertising
background image

9

W I R I N G

OPTIONAL CONNECTIONS (cont’d)

DIP SWITCH SELECTION

The release device will provide a factory default delay of 10
seconds (to minimize nuisance alarms) before releasing the
fusible link chain upon alarm or power loss. A 4-position DIP
Switch found on the PC board within the release device can be
used to adjust the length of the delay to one of four preset delays.
The optional delay settings are as follows:

1

2

3

4

Factory default setting of 10 seconds shown.

ON

NOTE: Position 4 is unused and should remain in the OFF position.
Position 3 is used to select one of the two available voice messages.

FIGURE 10

Delay Setting

Switch Position

1

2

3

4

10 Seconds

Off

Off

Off

Off

20 Seconds

Off On

Off

Off

30 Seconds

On

Off

Off

Off

60 Seconds

On

On

Off

Off

NOTE: Set all DIP switch options before applying power to the
system.

Advertising