ASSEMBLY AND INSTALLATION INSTRUCTIONS

1. Install the (

M6 screws into the ends of the

ceiling t-bar plate. Leave enough room to slide

over the ceiling grid bars. See fig 1
2. Install the (

ceiling pipe adapter onto the (#1)

using the hardware #2,4,8 & 9

Do not tighten at this time. See fig 2.
3. Determine where the 1 ½”pipe will be located in the ceiling. The FCP center point can be located
anywhere within 4 3/16” from any outer edge of the tile See fig 3 . Place a mark on the location and drill a
small hole through the ceiling tile.
4. Remove the tile adjacent to the tile where the pipe mount will be installed (for easy access).
5. Place the FCP ceiling kit into the grid and adjust the mount to the center of the pilot hole drilled into the
tile. See fig 3.
6. Using a pencil trace the inside of the CPA-800 onto the ceiling tile.
7. Remove the FCP and the ceiling tile
8. Using a knife, saw blade or hole saw, cutout the area marked by a pencil. Include enough clearance for the
pipe and lock screw (#12).
9. Replace the ceiling tile and the FCP mount into the ceiling grid. Check the alignment of the clearance hole
for the pipe and the hardware on the (#7) ceiling pipe adapter.

#3)

#1

#7) 1 ½”

plate

Leave the M6 screws on the ends to the

t-bar loose at this time.

M6 SCREW

FIG 1

FIG 3

T-BAR FRAME

CEILING TILE

5

CELING GRID

CEILING T BAR PLATE

CEILING PIPE
ADAPTER

4 3/16” TYP

FIG 2